Membrane Filter -
Jun
3

Bubble Testing for Membrane Filter

written by Yu

Bubble point is an important parameter for membrane filter. The bubble test is based on bubble point theory and is applicable to MF, UF, and MCF membranes. In conducting a bubble test, the module of interest is generally first removed from the membrane unit. The external shell of the module is then drained and pressurized [...]

Read More About - Bubble Testing for Membrane Filter »

May
20

Basic Principles of Membrane Filtration

written by Yu

For the purposes of the LT2ESWTR, a membrane filtration process is defined by two basic criteria:
1. The filtration system must be a pressure- or vacuum-driven process and remove particulate matter larger than 1 mm using an, engineered barrier, primarily via a size exclusion mechanism.
2. The process must have a measurable removal efficiency of a target [...]

Read More About - Basic Principles of Membrane Filtration »